Service work to be quoted:
(26)-10lb abc due for 6 year maintenance
(2)-10lb abc due for hydro test
(1)-10lb abc recharge
(1)-10lb abc new
(4)-5lb abc due for 6 year maintenance
(3)-5lb abc due for hydro test
(2)-2.5lb abc new
(3)-10lb co2 due for hydro test
(1)-5lb fe36 due for 6 year maintenance
Covington, GA 30014
Kenneth Y.
Annual Security Fence inspection. Includes visual only inspection for coverage and condition, including gap from ground level. This is for main location at 14187 Nisshinbo Drive only.
Annual visual inspection of perimeter lighting of building and street lighting in parking lot. Includes verification of light turning on and is for main location at 14187 Nisshinbo Drive only.
Annual hand-held radio coverage inspection. Includes verification of radio coverage between units from one end of the facility to the other. This is for main location at 14187 Nisshinbo Drive only.
Annual Portable Extinguisher Inspection (145) per NFPA 10.
BRC# 707019
Annual Emergency/Exit Light Inspection (167) per NFPA 101.
Annual Eye Wash Station Inspection (20)
Annual AED Inspection (2)
Annual Fire Door Inspection (8) per NFPA 80/1010 - includes replacement of fusible links
Monthly Safety Inspection including Portable Fire Extinguishers, Emergency/Exit Lights, Eye Wash Stations, and AEDs.
2018 PO# 57565
BRC
Covington, GA 30014
Troy L.
Alarm service Call AFP-200 is not working. Replaced batteries yesterday batteries quit working today. Advised that the circuit breaker makes a weird noise.
Covington, GA 30014
Troy L.
Access Control Installation
Covington, GA 30014
Troy L.
Covington, GA 30014
Troy L.
Alarm Systems Service Call
Covington, GA 30014
Luis M.
Covington, GA 30014
Luis M.
Covington, GA 30014
Bert P.
Alarm Systems and Distributed Communications Inspection
Annual Fire Alarm System Inspection (1) in NAMI1 per NFPA 72.
Annual Fire Alarm System Inspection (1) in NAMI2 per NFPA 72.
Annual EVAC/PA Inspection (1) per NFPA 25
Inoperable Deficiency: NAMI 2
Power Supply Above FACP had AC and Battery troubles prior Inspection. Need to investigate and repair.
FACP and FCPS Batteries have no Dates and need to be replaced (12v/7amp).
Covington, GA 30014
Bert P.
Sprinkler, Fire Hydrant, and Fire Pump Inspection
Annual Wet Sprinkler System Inspection (9) per NFPA 25
(9) at 14187 Nisshinbo Drive
Annual Fire Hydrant Inspection (3) per NFPA 25
Annual Fire Pump Inspection (1) per NFPA 25
Quarterly Sprinkler Inspection (9) per NFPA 25
(9) at 14187 Nisshinbo Drive
Covington, GA 30014
Kenneth Y.
Annual Portable Extinguisher Inspection (145) per NFPA 10.
Annual Emergency/Exit Light Inspection (167) per NFPA 101.
Annual Eye Wash Station Inspection (20)
Annual AED Inspection (2)
Annual Fire Door Inspection (8) per NFPA 80/1010 - includes replacement of fusible links
Monthly Safety Inspection including Portable Fire Extinguishers, Emergency/Exit Lights, Eye Wash Stations, and AEDs.
2018 PO# 57565
Deliver (1) 30 lb. Class D Copper Extinguisher
PO# 57112
Deliver (1) Amerex 859A extinguisher dolly (estimated price + $25 freight)
PO# 57113
Covington, GA 30014
Troy L.
Covington, GA 30014
Kenneth Y.
Monthly Safety Inspection including Portable Fire Extinguishers, Emergency/Exit Lights, Eye Wash Stations, and AEDs.
2018 PO# 57565
Annual Security Fence inspection. Includes visual only inspection for coverage and condition, including gap from ground level. This is for main location at 14187 Nisshinbo Drive only.
Annual visual inspection of perimeter lighting of building and street lighting in parking lot and around building. Includes verification of light turning on and is for main location at 14187 Nisshinbo Drive only.
Perimeter lighting mounted to the building are connected to timer in SWBD electrical rooms and can be activated. Lights on poles in parking lot and perimeter surrounds can be activated by covering the photocell on top of the light via lift.
Boom lift will be delivered on-site for usage. Please be sure to call off lift when completed.
Annual hand-held radio coverage inspection. Includes verification of radio coverage between units from one end of the facility t
Covington, GA 30014
Kenneth Y.
Portable Extinguishers Inspection
Monthly Safety Inspection including Portable Fire Extinguishers, Emergency/Exit Lights, Eye Wash Stations, and AEDs.
Check in with David Bland upon arrival. Add in lights at NAMI2. Make sure you have swaps for anything due we still need to swap out.
Deficiency: David would like a quote for 25 6v4 & 6v7 batteries
Covington, GA 30014
Kenneth Y.
Portable Extinguishers Inspection
Annual Fire Extinguisher Inspection
Covington, GA 30014
Bobby H.
Portable Extinguishers and Emergency / Exit Lights Inspection